代码之家  ›  专栏  ›  技术社区  ›  J86

带有AND和IN运算符的LEFT JOIN给出错误:在需要条件的上下文中指定的非布尔类型的表达式

  •  0
  • J86  · 技术社区  · 5 年前

    我正在尝试将MySQL查询移植到SQL Server。该查询在MySQL中运行良好,但在SQL Server中失败,并出现以下错误:

    在需要条件的上下文中指定的非布尔类型的表达式

    我怀疑这是因为SQL Server不喜欢我使用 AND 与 IN 左侧联接条件中的运算符。

    查询

    SELECT *
    FROM
      (SELECT dol.Id AS 'log_id',
              c.Id AS 'computer_id',
              COALESCE(r.processor_test, 'Skipped') as 'processor_test',
      COALESCE(r.display_test, 'Skipped') as 'display_test',
      COALESCE(r.storage_test, 'Skipped') as 'storage_test',
      COALESCE(r.network_test, 'Skipped') as 'network_test',
      COALESCE(r.keyboard_test, 'Skipped') as 'keyboard_test',
      COALESCE(r.mouse_test, 'Skipped') as 'mouse_test',
              COALESCE(user_fields.customer_id, 'None') AS 'customer_id',
              COALESCE(user_fields.order_no, 'None') AS 'order_no',
              COALESCE(user_fields.technician_id, 'None') AS 'technician_id',
              CONCAT('Customer ID: ', customer_id, '<br>Order No: ', order_no, '<br>Technician ID: ', technician_id) AS 'userfields',
              hd.Id AS 'hard_disk_id',
              dol.StartTime AS 'start_time',
              hd.Serial AS 'hard_disk_serial',
              CONCAT(hd.Gigabytes, ' GB') AS 'gigabytes',
              CONCAT('<b>Vendor: </b>', hd.Vendor, '<br><br><b>Model: </b>', hd.Product, '<br><br><b>Serial: </b>', hd.Serial, '<br><br><b>Size: </b>', hd.Gigabytes, ' GB<br><br><b>Pre-wipe SMART health status: ', dol.SmartOverallPre, '<br><br><b>Post-wipe SMART health status: ', dol.SmartOverallPost) AS 'target_drive_detailed',
              CONCAT('Vendor: ', hd.Vendor, '<br><br>Product: ', hd.Product, '<br><br>Serial: ', hd.Serial, '<br><br>Drive Media Type: ', hd.DriveMediaType , '<br><br>Size: ', hd.Gigabytes, ' GB<br><br><b>Interface: ', hd.Interface) AS 'drive_detailed',
              CONCAT(hd.Serial, ' (',hd.Gigabytes, ' GB)') AS 'target_drive',
              CASE
                  WHEN dol.PatternName = 'NIST 800-88r1 (recommended)' THEN 'NIST 800-88r1'
                  ELSE dol.PatternName
              END AS 'pattern_name',
              CASE
                  WHEN dol.Success = '1' THEN 'SUCCESS'
                  WHEN dol.Success = '0' THEN 'FAILED'
              END AS 'wipe_status',
              dol.Errors AS 'errors',
              dol.DirtySectors AS 'dirty_sectors',
              dol.Tool AS 'tool',
              dol.Kernel AS 'kernel',
              dol.JobUUID AS 'job_uuid',
              dol.UUID AS 'uuid',
              CONVERT(VARCHAR(20), dol.EndTime, 120) AS 'end_time',
              substring(CONVERT(VARCHAR(20), dol.EndTime, 120), 1, 11) AS 'end_time_short',
              dol.NumPasses AS 'num_passes',
              dol.TrimPasses AS 'trim_passes',
              dol.SectorsOverwritten AS 'sectors_overwritten',
              dol.SectorsNotOverWritten AS 'sectors_not_overwritten',
              dol.SectorsVerified AS 'sectors_verified',
              dol.CustomField AS 'custom_field_legacy',
              CASE
                  WHEN dol.NISTMethodTypeId = '1' THEN 'Unknown'
                  WHEN dol.NISTMethodTypeId = '2' THEN 'Clear'
                  WHEN dol.NISTMethodTypeId = '3' THEN 'Purge'
              END AS 'nis_method_type',
              CASE 
                  WHEN dol.DCOFound = '1' AND dol.DcoRemoved = '1' THEN CONCAT('Yes /</td><td> Yes', ' ') 
                  WHEN dol.DCOFound = '0' AND dol.DcoRemoved = '0' THEN CONCAT('No /</td><td> No', ' ') 
                  WHEN dol.DCOFound = '1' AND dol.DcoRemoved = '0' THEN CONCAT('Yes /</td><td> No', ' ') 
                  WHEN dol.DCOFound = '0' AND dol.DcoRemoved = '1' THEN CONCAT('No /</td><td> Yes', ' ') 
              END AS 'dco_foundremoved',
              CASE
                  WHEN dol.DCOLocked = '1' THEN 'Yes'
                  WHEN dol.DCOLocked = '0' THEN 'No'
              END AS 'dco_locked',
              CASE 
                  WHEN dol.HPAFound = '1' AND dol.HPARemoved = '1' THEN CONCAT('Yes /</td><td> Yes', ' ') 
                  WHEN dol.HPAFound = '0' AND dol.HPARemoved = '0' THEN CONCAT('No /</td><td> No', ' ') 
                  WHEN dol.HPAFound = '1' AND dol.HPARemoved = '0' THEN CONCAT('Yes /</td><td> No', ' ') 
                  WHEN dol.HPAFound = '0' AND dol.HPARemoved = '1' THEN CONCAT('No /</td><td> Yes', ' ') 
              END AS 'hpa_foundremoved',
              CASE 
                  WHEN dol.AMAXFound = '1' AND dol.AMAXRemoved = '1' THEN CONCAT('Yes /</td><td> Yes', ' ') 
                  WHEN dol.AMAXFound = '0' AND dol.AMAXRemoved = '0' THEN CONCAT('No /</td><td> No', ' ') 
                  WHEN dol.AMAXFound = '1' AND dol.AMAXRemoved = '0' THEN CONCAT('Yes /</td><td> No', ' ') 
                  WHEN dol.AMAXFound = '0' AND dol.AMAXRemoved = '1' THEN CONCAT('No /</td><td> Yes', ' ') 
              END AS 'amax_foundremoved',
              c.Vendor AS 'vendor',
              c.Model AS 'computer_model',
              c.ComputerSerial AS 'computer_serial',
              CONCAT('<b>Vendor: </b>', c.Vendor, '<br><br><b>Model: </b>', c.Model, '<br><br><b>Serial: </b>', c.ComputerSerial) as 'computer_summary',
              CONCAT('<b>Vendor: </b>', c.MotherboardVendor, '<br><br><b>Model: </b>', c.MotherboardModel) as 'motherboard_summary',
              CONCAT(first_cpu.Name, ' ', first_cpu.Speed) as 'cpu_summary',
              CONCAT(first_nic.Vendor, '<br><br>', first_nic.Product) as 'nic_summary',
              CONCAT(first_vc.Vendor, '<br><br>', first_vc.Product) as display_summary,
              CONCAT('<b>USB1 Ports: </b>', c.UsbPorts, '<br><br><b>USB2 Ports: </b>', c.Usb2Ports, '<br><br><b>USB3 Ports: </b>', c.Usb3Ports) as usb_ports,
              c.Memory AS 'computer_memory',
              hd.DriveMediaType AS 'hard_disk_drive_media_type',
              hd.Product AS 'hard_disk_product',
              hd.Vendor AS 'hard_disk_vendor'
       FROM DiskOperationLog dol
       LEFT JOIN
         (SELECT juf.JobUUID AS 'juf_job_uuid',
                 COALESCE(max(CASE
                                  WHEN juf.FieldName = 'Customer ID' THEN juf.FieldValue
                              END), 'None') AS customer_id,
                 COALESCE(max(CASE
                                  WHEN juf.FieldName = 'Order No' THEN juf.FieldValue
                              END), 'None') AS order_no,
                 COALESCE(max(CASE
                                  WHEN juf.FieldName = 'Technician ID' THEN juf.FieldValue
                              END), 'None') AS technician_id
          FROM DiskOperationLog dol
          INNER JOIN JobUserFields juf ON dol.JobUUID = juf.JobUUID
          GROUP BY juf.JobUUID) user_fields ON dol.JobUUID = user_fields.juf_job_uuid
       LEFT JOIN HardDisk hd ON hd.Id = dol.HardDiskId and (hd.Id, dol.EndTime) IN (select max(hd.Id) as Id, max(dol.EndTime) as EndTime from DiskOperationLog dol join HardDisk hd on hd.Id = dol.HardDiskId group by hd.Id)
       LEFT JOIN Computer c ON c.Id = hd.ComputerId
       LEFT JOIN
    (select t.computer_id, 
        MAX(
            CASE 
                WHEN Type='Processor' 
                THEN Result
                ELSE NULL
            END
        ) AS 'processor_test',
        MAX(
            CASE 
                WHEN Type='Display' 
                THEN Result
                ELSE NULL
            END
        ) AS 'display_test',
        MAX(
            CASE
                WHEN Type='Network' 
                THEN Result
                ELSE NULL
            END
        ) AS 'network_test',
        MAX(
            CASE 
                WHEN Type='Keyboard'
                THEN Result
                ELSE NULL
            END
        ) AS 'keyboard_test',
        MAX(
            CASE 
                WHEN Type='Mouse'
                THEN Result
                ELSE NULL
            END
        ) AS 'mouse_test',
        MAX(
            CASE 
                WHEN Type='Storage'
                THEN Result
                ELSE NULL
            END
        ) AS 'storage_test'
      from (    
        select c.Id as computer_id,
            hst.Type, 
            case min(
                case hst.Result 
                  when'Fail' then 1
                  when'Skipped' then 2
                  when'Pass' then 3
                end) 
              when 1 then 'Fail' 
              when 2 then 'Skipped'     
              when 3 then 'Pass'
            end Result
        from Computer c
        inner join HardwareTest ht on c.Id = ht.ComputerId
        inner join HardwareSubTest hst on ht.Id = hst.HardwareTestId
        group by c.Id, hst.Type
        ) t
     group by computer_id) r on c.Id = r.computer_id
       JOIN
         (SELECT *
          FROM Cpu cpu
          WHERE Id in
              (SELECT min(Id)
               FROM Cpu
               GROUP BY ComputerId)) AS first_cpu ON c.Id = first_cpu.ComputerId
       JOIN
         (SELECT *
          FROM Nic nic
          WHERE Id in
              (SELECT min(Id)
               FROM Nic
               GROUP BY ComputerId)) AS first_nic ON c.Id = first_nic.ComputerId
       JOIN
         (SELECT *
          FROM VideoCard vc
          WHERE Id in
              (SELECT min(Id)
               FROM VideoCard
               GROUP BY ComputerId)) AS first_vc ON c.Id = first_vc.ComputerId) AS query_result
    

    但我不确定为什么,使用 以及 在一个 LEFT JOIN 在SQL Server中受支持。我错过了什么?

    screenshot

    0 回复  |  直到 5 年前
        1
  •  3
  •   ouflak    5 年前

    SQL Server支持在JOIN中使用AND,但不能匹配多列。SQL server只允许一列。

    尝试使用以下内容更改您的加入:

       LEFT JOIN HardDisk hd 
       ON hd.Id = dol.HardDiskId 
       and hd.Id in (select max(hd.Id) from DiskOperationLog dol join HardDisk hd on hd.Id = dol.HardDiskId group by hd.Id)
       AND dol.EndTime in (select max(dol.EndTime) from DiskOperationLog dol join HardDisk hd on hd.Id = dol.HardDiskId group by hd.Id)
    
        2
  •  0
  •   Charlieface    5 年前

    正如另一个答案中所提到的,SQL Server不支持行值比较器。

    但是为了避免重复代码,您可以使用 APPLY

       OUTER APPLY (
          select
            MaxId = max(hd.Id),
            MaxEndTime = max(dol.EndTime)
          from DiskOperationLog dol2
          join HardDisk hd on hd.Id = dol2.HardDiskId
          group by hd.Id
       ) dol2
       LEFT JOIN HardDisk hd 
       ON hd.Id = dol.HardDiskId 
       and hd.Id = dol2.MaxId
       AND dol.EndTime = dol2.MaxEndTime
    

    我必须说,整个查询看起来可以使用大量的窗口函数,尤其是上面的这一部分。

        3
  •  0
  •   shawnt00    5 年前

    经过仔细阅读,我相信您的这部分查询绝对没有取得任何成果。我不确定比赛的目的是什么 dol.EndTime 但这不是正确的做法。

    LEFT JOIN HardDisk hd ON hd.Id = dol.HardDiskId and (hd.Id, dol.EndTime) IN (
       select max(hd.Id) as Id, max(dol.EndTime) as EndTime
       from DiskOperationLog dol join HardDisk hd on hd.Id = dol.HardDiskId group by hd.Id
    )
    

    我建议你改为以下内容,或者检查目标是什么,并更新你的问题:

    LEFT JOIN HardDisk hd ON hd.Id = dol.HardDiskId